Suzhou Electric Appliance Research Institute
期刊號(hào): CN32-1800/TM| ISSN1007-3175

Article retrieval

文章檢索

首頁(yè) >> 文章檢索 >> 往年索引

核電廠電氣設(shè)備抗震能力鑒定方法探討

來(lái)源:電工電氣發(fā)布時(shí)間:2019-01-21 13:21 瀏覽次數(shù):881
核電廠電氣設(shè)備抗震能力鑒定方法探討
 
阮善發(fā),初文婷,吳梅英
(河海大學(xué) 結(jié)構(gòu)抗震實(shí)驗(yàn)室,江蘇 南京 210098)
 
    摘 要:探討了核電設(shè)備抗震能力鑒定試驗(yàn)基本過(guò)程及評(píng)價(jià)方法,試驗(yàn)采用的阻尼比通常采用白噪聲掃描或正弦掃描的方法測(cè)得,提出了阻尼比及地震反應(yīng)譜量級(jí)的確定原則,確定鑒定結(jié)論的可接受性。針對(duì)目前抗震考核中電氣設(shè)備的安裝環(huán)境模擬存在不足之處,給出了改進(jìn)措施與方法。根據(jù)核電站不同電氣設(shè)備工作的復(fù)雜性和多樣性特點(diǎn),列出了幾種常用的電氣性能監(jiān)測(cè)電路原理圖,并給出了具體的電氣性能評(píng)價(jià)方法。
    關(guān)鍵詞:核電站;反應(yīng)譜;地震波;抗震能力鑒定;阻尼比
    中圖分類號(hào):TM506     文獻(xiàn)標(biāo)識(shí)碼:B     文章編號(hào):1007-3175(2019)01-0046-04
 
Discussion on Aseismatic Capability Qualification Method of Electrical Equipment for Nuclear Power Plant
 
RUAN Shan-fa, CHU Wen-ting, WU Mei-ying
(Laboratory of Structural and Aseismatic Engineering, Hohai University, Nanjing 210098, China)
 
    Abstract: This paper discussed the basic process and evaluation method of nuclear power equipment seismic capacity qualification test. The adopted damping ratio in the test could be obtained by white noise scanning or sinusoidal scanning.This paper proposed the certainty principle of damping ratio and earthquake response spectrum order and determined the acceptability of qualification conclusion.Aiming at the installation environment of electrical equipment in current aseismatic examination, this paper simulated the shortcomings and gave the improved measurements and methods.According to the complicated work and diverse characteristics of different electrical equipment in nuclear power plants, this paper listed the several kinds of common electrical performance monitoring circuit schematic and gave the specific evaluation methods for electrical performance.
    Key words: nuclear power station; response spectrum; seismic wave; shock resistance appraisal; damping ratio
 
參考文獻(xiàn)
[1] 王廣金,劉燕,劉江燕,等. 核電廠1E級(jí)電氣設(shè)備鑒定試驗(yàn)研究[J]. 核動(dòng)力工程,2008,29(4):131-134.
[2] 國(guó)家科委核安全中心. 核設(shè)備抗震鑒定試驗(yàn)指南:HAF·J0053[S]. 北京:國(guó)家核安全局,1995:9.
[3] 核工業(yè)部上海核工程研究設(shè)計(jì)院. 核電廠安全系統(tǒng)電氣設(shè)備抗震鑒定:GB 13625—1992[S]. 北京:國(guó)家質(zhì)量監(jiān)督檢驗(yàn)檢疫總局,1992:6.
[4] 李明成,林建,付明星,許本福,馬培峰. 核電廠1E級(jí)充電器及逆變器設(shè)備鑒定方案的研究[J]. 核安全,2014,13(2):77-82.
[5] 何延慶. 核電1E級(jí)電氣設(shè)備質(zhì)量鑒定[J]. 上海電器技術(shù),2004(3):14-19.
[6] 謝強(qiáng),王亞非,魏思航. 軟母線連接的變電站開關(guān)設(shè)備地震破壞原因分析[J]. 電力建設(shè),2009,30(4):10-14.