百萬機組制粉系統(tǒng)冷風門及混合風門回路改造
吳吉,呂映斌,柯榮宗
(神華福能發(fā)電有限責任公司,福建 泉州 362700)
摘 要:以某發(fā)電廠2×1 000 MW機組為例,介紹制粉系統(tǒng)控制策略、冷風門及混合風門的工作原理和故障現(xiàn)象,并結(jié)合設備日常維護特點及機組運行經(jīng)濟性,進行風門的控制回路現(xiàn)場改造,運行效果表明,改造后提高了機組運行的穩(wěn)定性,回路優(yōu)化效果比較理想。
關鍵詞:制粉控制系統(tǒng);風門控制原理;回路改造;回路優(yōu)化
中圖分類號:TM621 文獻標識碼:B 文章編號:1007-3175(2019)07-0062-03
Cold and Mixture Air Door Loop Transformation for Millions of Units Coal Pulverizing System
WU Ji, LYU Ying-bin, KE Rong-zong
(Shenhua Funeng Power Generation Co., Ltd, Quanzhou 362700, China)
Abstract: Taking the 2×1 000 MW unit in certain power station for example, this paper introduced the strategy of coal pulverizing control system and the working principle and fault phenomenon of cold and mixture air door. Combined with the characteristics of equipment routine maintenance and the unit operating economy, the site control loop of air door was carried out transformation. The operation effect shows that the transformation improves the stability of the unit operation and the effect of loop optimization is ideal.
Key words: coal pulverizing control system; throttle control principle; loop transformation; loop optimization
參考文獻
[1] 曹樹江,林榕. 斷路器操動機構(gòu)與繼電保護控制回路的協(xié)調(diào)與配合[J]. 繼電器,2005,33(24):72-77.
[2] 黃常抒,胡云花. 備自投裝置接線中的問題及應對措施[J]. 電力自動化設備,2009,29(4):147-149.
[3] 劉永興. 斷路器操作回路中防跳繼電器靈敏度的選擇[J]. 電力系統(tǒng)保護與控制,2009,37(9):116-119.