摘 要:針對當(dāng)前智能變電站自動化系統(tǒng)設(shè)備現(xiàn)狀背景及存在的問題,從技術(shù)發(fā)展趨勢上闡述了集中式測控技術(shù)研究的必要性。介紹了集中式測控的軟硬件架構(gòu)方案,分析了集中式測控實(shí)現(xiàn)的關(guān)鍵技術(shù)及難點(diǎn),并給出工程應(yīng)用實(shí)施方案。經(jīng)濟(jì)性分析對比表明,采用集中式測控技術(shù)可以較好地對現(xiàn)有二次設(shè)備進(jìn)行優(yōu)化整合,減少設(shè)備配置,降低設(shè)備調(diào)試維護(hù)工作量,提升了變電站建設(shè)經(jīng)濟(jì)效益。
關(guān)鍵詞:智能變電站;集中式測控;就地化
中圖分類號:TM63;TM734 文獻(xiàn)標(biāo)識碼:B 文章編號:1007-3175(2019)10-0029-07
Research and Application of Key Technology of Centralized Measurement and Control in Smart Substation
GONG Shi-min, TANG Bin, HONG Ying, ZHANG Lin, ZHAO Qian, CAI Liang-liang
(Guodian Nanjing Automation Co., Ltd, Nanjing 2111 00, China)
Abstract: Aiming at the current situation and existing problems of smart substation automation system, this paper expounded the necessity of centralized technology research from the trend of technology development. Introduction was made to the architecture of software and hardware for the centralized measurement and control. This paper analyzed the key technology and difficulty of realizing centralized measurement and control, giving the project application implementation plan. The comparison of economy analysis shows that the centralized monitoring and control technology can be used to optimize the integration of the second-equipment, to enhance the economic benefits of substation construction and to greatly reduce the equipment configuration and the equipment debugging and maintenance workload.
Key words: smart substation; centralized measure and control device; localization
參考文獻(xiàn)
[1] 國家電網(wǎng)公司. 智能變電站技術(shù)導(dǎo)則:Q/GDW 383—2009[S]. 北京:中國電力出版社,2009:2-12.
[2] 倪益民,楊宇,樊陳,等. 智能變電站二次設(shè)備集成方案討論[J]. 電力系統(tǒng)自動化,2014,38(3):194-199.
[3] 李瑞生, 李燕斌, 周蜂權(quán). 智能變電站功能架構(gòu)及設(shè)計(jì)原則[J]. 電力系統(tǒng)保護(hù)與控制,2010,38(21):24-27.
[4] 宋璇坤,李敬如,肖智宏,等. 新一代智能變電站整體設(shè)計(jì)方案[J]. 電力建設(shè),2012,33(11):1-6.
[5] 中國電力企業(yè)聯(lián)合會. 電力自動化通信網(wǎng)絡(luò)和系統(tǒng)第9-2 部分:特定通信服務(wù)映射( SCSM )——基于ISO/IEC 8802-3 的采樣值:DL/T 860.92—2016[S].北京:中國電力出版社,2006:2-12.
[6] 李孟超,允平,李獻(xiàn)偉,等. 智能變電站及技術(shù)特點(diǎn)分析[J]. 電力系統(tǒng)保護(hù)與控制,2010,38(18):59-62.
[7] 韓偉, 楊小銘, 仇新宏, 等. 基于數(shù)字化采樣的集中式保護(hù)裝置[J]. 電力系統(tǒng)自動化,2010,34(11):101-104.
[8] 孫一民,劉永新,章立宗,等. 智能變電站測控功能集中式冷備用裝置的研制[J]. 電力系統(tǒng)自動化,2015,39(18):97-100.