Suzhou Electric Appliance Research Institute
期刊號(hào): CN32-1800/TM| ISSN1007-3175

Article retrieval

文章檢索

首頁(yè) >> 文章檢索 >> 往年索引

三點(diǎn)式線路停電檢修作業(yè)平臺(tái)的研制

來源:電工電氣發(fā)布時(shí)間:2020-08-20 13:20 瀏覽次數(shù):792
三點(diǎn)式線路停電檢修作業(yè)平臺(tái)的研制
 
徐浩,王成,吳煒
(國(guó)網(wǎng)江蘇省電力有限公司檢修分公司淮安運(yùn)維站,江蘇 淮安 223001)
 
    摘 要:輸電線路停電更換500 kV懸垂絕緣子存在作業(yè)效率低、勞動(dòng)強(qiáng)度大、人員操作不便、費(fèi)時(shí)費(fèi)力等問題,研制了一種易攜帶、易操作的作業(yè)平臺(tái)裝置。該裝置采用輕質(zhì)高強(qiáng)度材料,硬梯頭部與作業(yè)相橫擔(dān)固定連接,能夠承受15 kN以上的外力,硬梯尾部與導(dǎo)線可靠連接。作業(yè)人員將架空平臺(tái)安裝后,沿著硬梯下到作業(yè)平臺(tái),并安全工作。該裝置可以使導(dǎo)線端人員作業(yè)時(shí)減少不必要的調(diào)整動(dòng)作,以達(dá)到安全、舒適、快速更換的工作要求,提升作業(yè)效率。
    關(guān)鍵詞:輸電線路;作業(yè)平臺(tái);絕緣子更換
    中圖分類號(hào):TM755     文獻(xiàn)標(biāo)識(shí)碼:B     文章編號(hào):1007-3175(2020)08-0060-04
 
Development of Three-Point Line Power Failure Maintenance Platform
 
XU Hao, WANG Cheng, WU Wei
(Huai'an Operation and Maintenance Station, State Grid Jiangsu Electric Power Co., Ltd Maintenance Branch Company, Huai'an 223001, China)
 
    Abstract: The replacement of 500 kV suspension insulators in the power transmission line has problems such as low work efficiency, high labor intensity, inconvenient operation, time-consuming and labor-intensive operation, etc. A work platform device that is easy to carry and easy to operate has been developed. The device adopts light-weight and high-strength materials. The head of the hard ladder is fixedly connected with the cross arm of the work phase, which can withstand external forces of more than 15 kN, and the tail of the hard ladder is reliably connected to the wire. After installing the overhead platform, the operator descends to the operating platform along the hard ladder and works safely. The device can reduce unnecessary adjustment actions when the wire end personnel work, so as to meet the work requirements of safety, comfort and quick replacement, and improve work efficiency.
    Key words: transmission line; operating platform; insulator replacement
 
參考文獻(xiàn)
[1] 肖春偉,孫君錄,申思勉. 帶電更換高壓輸電線路耐張絕緣子方法探討[J]. 河南電力,2014(4):37-39.
[2] 陳忠華,鄔韋華,沈佳. 新型絕緣子鎖緊銷拔銷器的研制[J]. 浙江電力,2014(1):26-29.
[3] 趙玉良,李運(yùn)廠,戚暉,等. 高壓線路帶電作業(yè)智能化自動(dòng)工具研究[J]. 制造業(yè)自動(dòng)化,2012,34(3):12-14.
[4] 史磊,曹志全,李曉兵,等. 帶電更換750 kV線路直線單串復(fù)合絕緣子技術(shù)實(shí)踐與改進(jìn)[J]. 電網(wǎng)與清潔能源,2011,27(9):41-44.
[5] 胡毅,劉凱. 超/ 特高壓交直流輸電線路帶電作業(yè)[M]. 北京:中國(guó)電力出版社,2011.
[6] 鄒德華,江維,吳功平,等. 輸電線路絕緣子更換帶電作業(yè)機(jī)器人控制方法[J]. 高壓電器,2016,52(10):92-98.
[7] 溫帶銀. 淺談架空輸電線路絕緣子更換工作[J].中國(guó)高新技術(shù)企業(yè),2012(6):142-144.
[8] 孔偉,孟遂民. 架空送電線路設(shè)計(jì)[M]. 北京:中國(guó)電力出版社,2007.
[9] 李景忠. 整體更換500 kV耐張絕緣子串施工工藝分析[J]. 機(jī)電信息,2013(27):127-128.