變電站直流斷路器選型配置及級差配合研究
李偉,束娜,胡衛(wèi)清,韓本帥
(山東電力工程咨詢院有限公司,山東 濟(jì)南 250013)
摘 要:介紹了直流斷路器作為直流系統(tǒng)元件的重要性,分析對比了新舊版《電力工程直流系統(tǒng)設(shè)計(jì)技術(shù)規(guī)程》的差異,通過研究直流斷路器選型配置和級差配合的要求,并以實(shí)際工程為案例,結(jié)合現(xiàn)場調(diào)試和數(shù)據(jù)分析,得出了直流斷路器的選配方法,指導(dǎo)了設(shè)計(jì)單位對新版直流規(guī)程的應(yīng)用,保證了直流系統(tǒng)的設(shè)計(jì)可靠性。
關(guān)鍵詞:直流規(guī)程;直流斷路器;選型;級差配合
中圖分類號:TM561 文獻(xiàn)標(biāo)識(shí)碼:B 文章編號:1007-3175(2016)05-0060-03
Research on Type Selection and Stage Difference Coordination of Direct Current Circuit Breaker in Substation
LI Wei, SHU Na,HU Wei-qing, HAN Ben-shuai
(Shandong Electric Power Engineering Consulting Institute Corp. Ltd, Jinan 250013, China)
Abstract: Introduction was made to the significance of the direct current (DC) circuit breaker as one DC system component. This paper analyzed and compared the difference between electric power project DC system design technical code of new version and that of old one. This paper researched on the requirement of the type selection and stage difference coordination of DC circuit breaker. Taking real project for case and combining with the on-site debugging and data analysis, this paper obtained the type selection and coordination method, which guides?the application of new DC technical code for the designers, and also ensures the design reliability of DC system.
Key words: direct current technical code; direct current circuit breaker; type selection; stage
參考文獻(xiàn)
[1] 李秉宇,郝曉光. 變電站直流系統(tǒng)保護(hù)級差配合特性分析[J]. 低壓電器,2011(6):51-54.
[2] 劉毅, 周雒維, 陳國通. 直流系統(tǒng)保護(hù)電器級差配合的研究[ J ] . 電力系統(tǒng)保護(hù)與控制,2011,39(2):45-49.
[3] 周鋒. 電力系統(tǒng)直流斷路器短路級差配置研究[J].通信電源技術(shù),2011,28(4):58-60.
[4] DL/T 5044—2004 電力工程直流系統(tǒng)設(shè)計(jì)技術(shù)規(guī)程[S].
[5] DL/T 5044—2014 電力工程直流系統(tǒng)設(shè)計(jì)技術(shù)規(guī)程[S].